Dr Paul Wang:                   Welcome to the monthly podcast On the Beat for Circulation: Arrhythmia and Electrophysiology. I'm Dr Paul Wang, Editor in Chief, with some of the key highlights from this month's issue.

                                                In our first paper Lucas Boersma and associates examined the final two-year outcome data from 47 centers, in 1,020 patients receiving the left atrial appendage occlusion watchman devices. Their study population had a mean age of 73.4 years, with 311 having prior ischemic stroke or TIA, 153 having prior hemorrhagic stroke, and 318 having prior major bleeding. 49% had a CHAS II vast score of 5 or greater, and 40% had a HAS-BLED score of three or greater. Oral anticoagulation was contraindicated in 72%. During follow up, 161 patients, or 16.4% died, 22 strokes were observed or 1.3 per 100 patient years representing an 83% reduction versus historic data. And 47 major non-procedural bleeding events were observed, or 2.7 per 100 patient years representing a 46% reduction versus historic data.

                                                Device thrombus was observed in 34 patients or 4.1%, and was not correlated to the drug regimen during follow up. P=0.28.

                                                In our next paper, Anish Amin and Associates examined whether high voltage impedance and subcutaneous or SICD system implant position are associated with ventricular fibrillation or VF conversion success with a sub-maximal joule shock. In the SICD investigational device exemption study, a successful conversion test required two consecutive VF conversions at 65 joules in either shock vector. Sub-optimal device position was defined as an inferior electrode or pulse generator, or electrode coil depth of greater than three mm anterior to the sternum, based on chest radiograph. Of 314 patients who underwent SICD implantation, 282 patients were included in this analysis. There were 637 inductions to test defibrillation at 65 joules. 62 conversion failures, or 9.7%, occurred in 42 or 14.9% of patients.

                                                Lower body mass index or BMI, and lower shock impedance, were associated with higher conversion success rate. Whereas white race was associated with lower conversion success rate. Sub-optimal position was more common in obese patients. Inferior electrode and greater distance between the lead and sternum were associated with a higher impedance. When appropriate system position was achieved, conversion failure was not associated with high BMI.

                                                In our next paper, Je-Wook Park and associates examined the left atrial pressure after repeat radiofrequency catheter ablation procedures. Among 1,848 patients who underwent atrial fibrillation or AF catheter ablation, the authors measured the left atrial pressure, LAP, immediately following the transseptal puncture in sinus rhythm in 1,687 patients before De novo ablation, median age 59 years, 72.4% male and 72.8% paroxysmal AF, and in 142 with second procedures. In the same 142 patients, the degree of left atrial stiffness, reflected by LAPP, the difference between LAP peak and LAP nater, was significantly higher in the second procedure than in the De novo procedure. P<0.001. The degree of LAPP increase, delta LAPP, was significantly higher in patients who underwent additional extra pulmonary vein left atrial ablation than in those who underwent circumferential PV isolation alone. P=0.01. Extra pulmonary vein left atrial ablation was independently associated with delta LAPP. P=0.045.

                                                An increase LAPP during repeat procedures was independently associated with a reduced diastolic function. P=0.041. However, the EQ5D symptom score did not change after de novo ablation.

                                                In our next paper, Adam Graham and associates examined a median of 711 electrocardiographic imaging, or ECGI, in cardiopirin points per patient to compare simultaneous epicardial mapping using CARTO and ECGI after geometrical co registration in 8 patients. They found that the correlation coefficient measuring the similarity of activation times we equal to 0.66, and the correlation coefficient for repolarization times was 0.55. The minimum distance between epicardial pacing sites, and the region of earliest activation in ECGI was 13.2 mm. Range 0 to 28.3 mm, from 25 pacing sites with stimulation to cuirass interval less than 40 milliseconds.

                                                In our next paper, Michael Barkagan and associates examined high-current, short-duration radiofrequency energy delivery using and expandable spheroid-shaped lattice electrode with effective service tenfold larger than standard irrigated electrodes. It incorporated nine surface temperature sensors, with ablation

Mark as Played

Advertise With Us

Popular Podcasts

Dateline NBC
The Nikki Glaser Podcast

The Nikki Glaser Podcast

Every week comedian and infamous roaster Nikki Glaser provides a fun, fast-paced, and brutally honest look into current pop-culture and her own personal life.

Stuff You Should Know

Stuff You Should Know

If you've ever wanted to know about champagne, satanism, the Stonewall Uprising, chaos theory, LSD, El Nino, true crime and Rosa Parks, then look no further. Josh and Chuck have you covered.

Music, radio and podcasts, all free. Listen online or download the iHeart App.

Connect

© 2024 iHeartMedia, Inc.